调幅射频电磁场人体辐照实验系统的设计与实现Design and implementation of human body irradiation experimental system for amplitude-modulated radiofrequency electromagnetic field
蓝茂英,蔡林波,邓官华,段松,熊威,李晓东,辛学刚
摘要(Abstract):
设计可用于调幅射频电磁场生物效应研究的人体辐照平台,分别从硬件系统部分和软件系统部分两方面进行介绍。硬件系统由射频信号发生模块、功率放大模块、阻抗匹配模块以及发射天线构成,其接收到由软件系统发出的载波、调制频率、调制深度以及功率参数指令后,进而实时产生相应的调幅射频电磁场。实际测量结果表明,设计的调幅射频电磁场人体辐照实验系统具有良好的性能参数,该系统为人体调幅射频电磁场生物效应研究提供一个使用方便、参数可控的电磁辐照平台。
关键词(KeyWords): 调幅射频电磁场;生物效应;电磁辐照系统;电磁仿真;FDTD;匹配电路
基金项目(Foundation): 国家重点研发计划项目(2016YFC010080);; 国家自然科学基金项目(61172034);国家自然科学基金项目(61528102);国家自然科学基金项目(61671229);; 广东省自然科学基金项目(2015A030313234);; 广东省省级科技计划项目(2015B020214006;2016A050502026);; 上海科技计划项目(15441907500)~~
作者(Author): 蓝茂英,蔡林波,邓官华,段松,熊威,李晓东,辛学刚
DOI: 10.16652/j.issn.1004-373x.2018.06.025
参考文献(References):
- [1]ISRAEL M,ZARYABOVA V,IVANOVA M.Electromagnetic field occupational exposure:non-thermal vs.thermal effects[J].Electromagnetic biology&medicine,2013,32(2):145-154.
- [2]NIE Y,DU L,MOU Y,et al.Effect of low frequency magnetic fields on melanoma:tumor inhibition and immune modulation[J].BMC cancer,2013,13(1):582-593.
- [3]STUPP R,TAILLIBERT S,KANNER A A,et al.Maintenance therapy with tumor-treating fields plus temozolomide vs temozolomide alone for glioblastoma:a randomized clinical trial[J].Jama,2015,314(23):2535-2543.
- [4]BENEDUCI A,COSENTINO K,ROMEO S,et al.Effect of millimetre waves on phosphatidylcholine membrane models:a non-thermal mechanism of interaction[J].Soft matter,2014,10(30):5559-5567.
- [5]BARBAULT A,COSTA F P,BOTTGER B,et al.Amplitudemodulated electromagnetic fields for the treatment of cancer:discovery of tumor-specific frequencies and assessment of a novel therapeutic approach[J].Journal of experimental&clinical cancer research,2009,28(1):51.
- [6]COSTA F P,DE OLIVEIRA A C,MEIRELLES R,et al.Treatment of advanced hepatocellular carcinoma with very low levels of amplitude-modulated electromagnetic fields[J].British journal of cancer,2011,105(5):640-648.
- [7]ZIMMERMAN J W,PENNISON M J,BREZOVICH I,et al.Cancer cell proliferation is inhibited by specific modulation frequencies[J].British journal of cancer,2012,106(2):307-313.
- [8]PAFFI A,APOLLONIO F,LOVISOLO G A,et al.Considerations for developing an RF exposure system:a review for in vitro biological experiments[J].IEEE transactions on microwave theory and techniques,2010,58(10):2702-2714.
- [9]PAFFI A,MERLA C,PINTO R,et al.Microwave exposure systems for in vivo biological experiments:a systematic review[J].IEEE transactions on microwave theory and techniques,2013,61(5):1980-1993.
- [10]PAFFI A,APOLLONIO F,LOVISOLO G A,et al.Exposure systems for bioelectromagnetic investigations in the radiofrequency range:classification and emerging trends[C]//Proceedings of the 5th European Conference on Antennas and Propagation.Rome:IEEE,2011:3159-3163.
- [11]Agilent Technologies Inc.User′s guide:N5182A MXG vector signal generators[M].Santa Clara:Agilent Technologies Inc.,2006.
- [12]ROGERS J,PLETT C.Radio frequency integrated circuit design[M].Boston:Artech House,2003.
- [13]GABRIEL C.Compilation of the dielectric properties of body tissues at RF and microwave frequencies:AL/OE-TR-1996-0037[R].San Antonio:Air Force Material Command,Brooks Air Force Base,1996.
- [14]TAFLOVE A,HAGNESS S C.Computational electrodynamics[M].Boston:Artech House,2000.
- [15]IEEE C95.1-2005.IEEE standards for safety levels with respect to human exposure to radio frequency electromagnetic fields,3 k Hz to 300 GHz[S].New York:Institute of Electrical and Electronics Engineers,2005.